AE-400 It produces with high velocity air to neutralize the static charge and re-attraction of contamination. Its rugged construction allows it to have excellent performance. Ionizing points are housed in a rigid copper bar .It requires our Power Supply for operation, which must be ordered separately. Specification: Operating Voltage 5.6 KV Current Consumption 230 ¼ a Operating Temperature 0~50 Weight 2.8kg/M Max. Length 2 Metres H.V Cable 3 Metres Air Consumption 10 Lpm/hole Decay Test Results: Distance Decay Time With compressed air 100mm 0.2s 300mm 0.6s 400mm 0.4s 500mm 0.8s 600mm 0.9s Remarks: 1.Distance measured in mm,decay time measured in seconds. 2.Test data available using ME 268A Charged Plate Analyzer. 3.Test figures are subject to variation in the atmospheric conditions.