BINDER, Drying Oven, Drying and heating chambers with forced convection
Priceinquiry
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Quantity1 unit
Pack. & Deliveryper unit
OriginGermany
Model : FD 23
Capacity : 20 liter

A BINDER FD series drying oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous temperature distribution, quick dynamics and powerful fan, it saves valuable time.

Advantages:

* Fast, even tempering
* Wide temperature range
* Quality " Made in Germany"

Exterior dimensions
Width ( mm) 435
Height ( incl. feet) ( mm) 495
Depth ( mm) 520
Plus door handle and connection ( mm) 85
Wall clearance, rear ( mm) 100
Wall clearance, side ( mm) 100
Exhaust duct ( outer Ø mm) 52
Steam space volume ( l) 36
Number of doors ( ea.) 1

Interior dimensions
Width ( mm) 222
Height ( mm) 330
Depth ( mm) 277
Interior volume ( l) 20
Racks ( number standard/ max.) 2 / 3
Load per rack ( kg) 12
Permitted total load ( kg) 25
Weight ( empty) ( kg) 33

Temperature data
Temperature range approx. 5 ° C above ambient temperature to ( ° C) 300
Temperature variation
at 70 ° C ( ± K) 0, 8
at 150 ° C ( ± K) 2, 2
at 300 ° C ( ± K) 4, 3
Temperature fluctuation at 70 ° C ( ± K) 0, 3
Warm-up time 1)
to 70 ° C ( min.) 7
to 150 ° C ( min.) 22
to 300 ° C ( min.) 45
Recovery time after doors were open for 30 sec. 1)
at 70 ° C ( min.) 2
at 150 ° C ( min.) 4
at 300 ° C ( min.) 9

Ventilation data
Ventilation
at 70 ° C ( x/ h) 59
at 150 ° C ( x/ h) 64
at 300 ° C ( x/ h) 53

Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage ( ± 10% ) 50 / 60 Hz ( V) 230
Nominal power ( kW) 0, 8
Energy consumption
at 70 ° C ( W) 145
at 150 ° C ( W) 300
at 300 ° C ( W) 720