Thermoreactors VELP, model ECO 8, Italy
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
OriginItaly

Specification

The ECO 8 thermoreactor is used to determine parameters such as COD an nitrogenous and phosphorated compound content in test-tube samples. Safe and reliable conditions are ensured by the test tube cover, the heating block shield and the safety thermostat. Five different working temperatures ( 70, 100, 120, 150 and 160° C) and working time in minutes ( 30, 60, 120 and continuous) can be set. An acoustic signal and automatic switching off at the end of cycle.
The aluminum heating block offers optimum thermal homogeneity at all selected temperatures.
Heating block temperature is controlled by a PID logic microprocessor.

GENERAL FEATURES

Construction material: Epoxy painted metal structure

Holes number and diameter: 8 with ext. Ø 16 mm and 1 hole ext. Ø 22mm ( sludge analysis)

End of the cycle: acoustic signal with automatic switch-off

Power: 140 W

Power supply: 115 V and 230 V / 50-60 Hz

Weight: 2 kg ( 4.4 lb)

Dimension ( WxHxD) : 135x95x230 mm ( 5.3x3.7x9.1)

PERFORMANCES

Selectable working temperatures: 70, 100, 120, 150 and 160° C

Selectable working time: 30, 60, 120 min or continuous

Automatic adjustment of the voltage: 230 V or 115 V

HEATING BLOCK TECHNICAL DATA

Temperature stability: ± 0, 5° C

Temperature homogeneity: ± 0, 5° C

Temperature precision: ± 1° C

Overtemperature safety

SIGNALS

Reaching of set temperature: acoustic and visual signal

Count-down: visual

End of cycle: acoustic and visual signal

Probe interruption: acoustic and visual signal

Broken probe: acoustic and visual signal

Exceed temperature range: acoustic and visual signal