nano measurement ( Pengukur level ketinggian cairan)
SENSOR & INSTRUMENT FOR NANO TECHNOLOGY SOLUTIONS
Measurements using eddy-current sensors are the best choices when you have to measure the precision in the measurement area of rough, dirty or extreme ( read: harsh environment) . The presence of non-metallic materials, plastic, oil or water in the area of measurement, even though the magnetic field will not affect the value of the measurement. These sensors can survive in a dynamic medium-pressure ( up: 4000bar) however, its accuracy can still achieve a resolution of one nanometer or even less than that.
New capacitive transducer system with resolution / accuracy up to sub-nanometre ( under nanometers) ,
Not long ago, after introducing capacitive method of measuring single-channel types, we now re-introduce multi-channel capacitive transducer, which has a very extreme resolution ( sampi per-100 nanometer, 0.01nm) . With a customized design, the number of measurement channels used can achieve 8 channels per unit and is very supportive for
samapi distributed sensor measurements with 20m distance from the base unit. Can work in temperatures -50 ° C to 200 ° C. Synkronisasi measurement can be performed even if the measuring object is not connected with the ground. And recalibration is not necessary even though the replacement sensor.
Measurement of Nano-Chromatic confocal resolution using Non-Contact Displacement Transducer.
Confocal displacement transducer is a sensor for precision measurement applications. Available with standard or miniature form that is unique to specific measurements.
Transducer was used to measure the various types of surfaces and can be used to measure the thickness from one side of the translucent material objects.
Replacement of the sensor is very easy and fast
Measurement of Nano-Chromatic confocal resolution using Non-Contact Displacement Transducer
Confocal displacement transducer is a sensor for precision measurement applications. Available with standard or miniature form that is unique to specific measurements.
Transducer was used to measure the various types of surfaces and can be used to measure the thickness from one side of the translucent material objects
Thickness measurement Sleeves
Pengukran method the thickness of the two sides with two sensors tersingkronisasi
Measurement of the thickness measurement of glass thickness from one-sided
Height of liquid level gauge
- Liquids Electrolit
- Liquids capacitor
- Liquid Chemicals, etc.
Surface scan:
- Electronic components
- Semiconductor
- Etc.
Distributor, Agent, Sales, Installation and Training.
Jakarta - Indonesia
Contact Person: Syafei ( 0815 614 1954 / 0811 893 101)
Address: Jl. Pahlawan Revolusi No. 22B
Telp. + 62-21-8611 131, 8611 259, 8611 444, 8611449
Fax : + 62-21-8611 207
EMAIL : sales@ alatperaga.com