Welcome to
A & E Laboratory Instruments Co., Ltd.
Free Member
A & E Laboratory Instruments Co., Ltd.
China
Home
Company Info
Contact Us
Trade Offers
[18]
Selling Offers
[18]
Share your thoughts
Write a review
Recommend to your friends
Language
English
Sell
Turbidity Meter
Quantity Order:
Origin:
China
Payment Method:
Cashier Order
A & E Laboratory Instruments Co., Ltd.
E-mail: sales@ aelab.com.cn
Website 1: www.aelab.com.cn
Website 2: www.aelabcn.com
Application:
This instrument is measured by detecting and quantifying the scattering of light in water ( solution) . It is designed for turbidity measurement in accordance with International Turbidity Measurement Standard ISO 7027.
It widely apply to the turbidity measurement in Waterworks, Life Sewage Treatment Plants, Drink Factories, Environmental Protection Departments, Process Water, Brewage & Drugs Manufactures, Guard Departments, Hospital, etc.
Features:
# Compact in size, novel in design & LCD display with suitcase package..
# Succinct operation, suitable measurement range & higher performance.
# Low daft, High Accuracy, Nice Stability ensure long-time & stable running.
# Unique positioning structure & high precision pptical system effectively guarantee measuring values accuracy and repeatability.
# Lower consumption and AC & DC power supply convenience for operating outside or laboratory.
# With low voltage indication function remand of users replace battery timely.
# With data output interface.
Specifications:
Model: WGZ-B
Measurement Principle: 90° Scattered light
Minimum Readout: 0.1
Measurement Range ( NTU) : 0-200
Basic Error: ± 2.5% F.S
Repeatability: d1.5%
Zero Draft: 0.2
Power Supply: Power adapter & battery
Model: WGZ-1B
Measurement Principle: 90° Scattered light
Minimum Readout: 0.01
Measurement Range ( NTU) : 0-20
Basic Error: ± 2.5% F.S
Repeatability: d1.5%
Zero Draft: 0.1
Power Supply: Power adapter & battery
Model: WGZ-1
Measurement Principle: 90° Scattered light
Minimum Readout: 0.01
Measurement Range ( NTU) : 0-20, 0-200
Basic Error: ± 2.5% F.S
Repeatability: d1.5%
Zero Draft: 0.1
Power Supply: Power adapter & battery
Model: WGZ-2AB
Measurement Principle: 90° Scattered light
Minimum Readout: 0.01
Measurement Range ( NTU) : 0-20, 0-200, 0-500
Basic Error: ± 2% F.S
Repeatability: d1%
Zero Draft: 0.1
Power Supply: Power adapter & battery
Model: WGZ-2B
Measurement Principle: 90° Scattered light
Minimum Readout: 0.001
Measurement Range ( NTU) : 0-20, 0-100, 0-200
Basic Error: ± 2% F.S
Repeatability: d1%
Zero Draft: 0.02
Power Supply: Power adapter & battery
Model: WGZ-3B
Measurement Principle: 90° Scattered light
Minimum Readout: 0.001
Measurement Range ( NTU) : 0-10, 0-100, 0-1000
Basic Error: ± 2% F.S
Repeatability: d1%
Zero Draft: 0.02
Power Supply: Power adapter & battery
Model: WGZ-4000B
Measurement Principle: 90° Scattered light
Minimum Readout: 0.001
Measurement Range ( NTU) : 0-10, 0-100, 0-1000, 0-4000
Basic Error: ± 2% F.S
Repeatability: d1%
Zero Draft: 0.02
Power Supply: Power adapter & battery