Sign In
|
Sign Up
Indomonster Priority
16th Year
PT Masramandiri
http://indomonster.com/masramandiri/
Home
Company Info
Products Catalog
Contact Us
Recommend Us
MASRAMGROUP. PT MASRAMANDIRI . General supplier - Contractor-Manufacturing (Medium & Low Voltage Switchboard, Motor Control Center, Generator Control-Synchronizing, AMF, Capacitor Bank , Rectifier & Battery Charger)
Products Catalog (60)
Semaphore, Switch....
CRE Technology, ....
CRE Technology....
CRE Technology XGEN 1.5....
CRE, Technolology....
CRE Technology UNIGEN....
CRE Technology GENSYS 2....
MASTER 2.0 CRE....
CRE Technology GENSYS 2....
SF6 Gas Insulated LBS....
See all items
Contact Information
Name:
Mrs. Suzan R [Director/CEO/General Manager]
E-mail:
Phone Number:
Mobile Number:
Fax Number:
Address:
Ruko Kav - M.10 No.15 Desa Pasirsari Jl. Raya Industri Lippo Cikarang
Bekasi 17550, Jawa Barat
Indonesia
E-mail : masrammandiri@ yahoo.com, Contact Person: + 62-21 33445179 ( Mr. Rizki) , Technical : 08388153616 ( Mr. Ahmad) , Cabang Surabaya : Perum Taman Pondok Legi 3 Blok T22 Surabaya tel.031-8537881, 031-70741585, fax.031-8537881, mobile.085850033508
Average User Review
There is no review for this company
Write a review
Language :
Products Catalog
LBS 630A, 24 kV, 16 kA - Unisarc
[Dec. 30, 2009 2:24:06]
Price
nego
Quantity Order:
Payment Method
Telegraphic Transfer (T/T)
Pack. & Delivery
packing
Origin
Italy
Recommend to your friends
Specification
The LBS is a three phase air ` puffer` load break switch. On each phase, the cylindrical moving contact also acts as an air piston during opening.The fixed contact on the incoming terminal includes an arc conductor rod which channels the arcing plasma to within the air piston after the main contacts are seperated. The compressed air generated by the moving contact/ air piston in the opening motion then blows, deionizes and extinguishes the arc.
The three phases are mounted on a chasis which also mounts a fault-making earth switch. The LBS is also built to house HV HRC fuses. A stored energy mechanism on the LBS allows for shunt tripping and fuse triggered tripping. The LBS can be manually operated or motor operated.
Every unit of LBS is built with an interlock mechanism which ensures proper operational sequence between the load break switch, the earth switch and the access to the service cubicle of the panel
TECHNICAL DATA FOR LBS
Rated voltage ( kV) 12 17.5 24
Rated current ( A) 400/ 630 400/ 630 400/ 630
Frequency ( Hz) 50-60 50-60 50-60
Apply voltage 50Hz/ 1min ( kV) 42 48 50
Impulse test voltage ( kV) 85 95 125
Short circuit breaking capacity ( wtih fuses) ( kA) 50 50 50
Overload breaking capacity ( of contacts only) ( A) 1600 1300 1000
No load transformer breaking capacity ( A) 16 20 25
No load cable breaking capacity ( A) 10 16 25
Rated short-time current ( kA/ sec) 20/ 2 20/ 2 20/ 2
Making capacity ( kA) 50 50 50
Dielectric strength for earth switch ( kA/ sec) 20/ 2 20/ 2 20/ 2
Mechanical life ( C-O cycles) 4000 4000 4000
Electrical life at nomimal current ( C-O cycles) 500 400 300