Specification :
1. Description:
Pet immune PIR motion detector is designed with high technology. It features
high anti-magnetism, anti-light, Pet friendly, induction direction identified, low
power alert, temper switch,auto-temperature compensation and lowest power
consumption. Widely used for window, veranda, aisle and so on.
2. Specification
1) Sensor: Dual passive infrared (imported), lowest noise.
2) Pet immune: about 15kg.
3) Voltage: DC3V Current: 40uA (stand by)
4) Output time: 2second
5) Alert time between two alert: 6 second
6) Low batter indicator: Led flash one time per 5 second
7) Detected range: 110°*9m(max when setting for induction direction identified)
110°*12m(max without induction direction identified )
8) Frequency: 433/315MHZ(optional)
9) Transmitter distance:>180m (open area)
10) Size:110×70×40mm
11) Temperature: 20^55
12) Humidity: 10^`93
3. Installation
1). Coding address: preset by manufacture or by user. If not , please refer to code
diagram to set it.
Install the detector to the proper place where intruder must enter.
Do not face the detector to any area where window, lamp-house,heat thing and so on.
It is used for indoor,not for outdoor.
Installing height suggested: 1.5~2.5 m
2).When power is on, LED flashed , it is initialized time, please do not walk in its
detected range. After flashed again in a few seconds. It starts to normal work.
3).LED
Flashed three timessend alert
Flashed five timesdetected somebody from inside going outside, it will not send alert.
4).Operation setting
A jumper: LED output optional, no jumper,no output, with jumper output indicator
JP3:
F jumper: with jumper to have maximum distance.
M jumper: with jumper to have normal medium distance (default)
N : F M N : no jumper to have nearest distance.
5).Walk test
Normal test: when the detector enters into working mode after three minute,
walk for ten times to test it. Test in two times must be over seven seconds. Ensure
each time has affective alert. O r, you should change the angle to fit the demand.
NOTE: in more far range, it is normal for the detector to delay to send alert.
4. Caution: .
When installing, do not drop down or hit the detector so to avoid the internal infrared
sensor.
Do not touch the sensor lens so to avoid the detecting distance and sensitivity.
Choose proper returning time to avoid alert.
Have termly walk test