Welcome to
CV ANDALAN PRIMA SEJAHTERA

Free Member
CV ANDALAN PRIMA SEJAHTERA
CV ANDALAN PRIMA SEJAHTERA
Indonesia
Share
Welcome to
CV ANDALAN PRIMA SEJAHTERA

http://indomonster.com/andalanps


B1. Temperature
B2. Flow
B3. Fill Level / Limit Valvue / Level
B4. Analysis
B5. Humidity
B6. Pressure
B7. Weighing Instruments
B1. Temperature
The measuring and monitoring of temperature with resistance thermometers or thermocouples is the most common method to watch and control processes. Here the temperature gets a electrical unit by using the thermoelectric effect ( thermocouple) or a resistance change. This measuring value can be converted to standard signals by our transmitter for further usage.
Industrial measurement and control technology
Process measurement
Pipeline and tank construction
Furnace construction
Plastics industry
Food industry
Surface measurements
Plant and machine construction
Room temperature measurement
EX - applications
SIL 2 - applications

> Temperature probes
> Temp.probes + data logger
> Temp.probes + transmitter
> Transmitters
> Temperature monitors
> Displays
> Accessories
B2. Flow
Piston, Valve Design
Piston, Inline Design
Variable Area
Dynamic Diaphragm
Paddle
Calorimetry
Rotor, Inline
Rotor, Inline Model
Rotor, Probe Form
Turbine
Gearwheel
Magnetic Inductive, Inline Model
Magnetic Inductive - Probe Form
Spindle ( Screw)
Vortex
Sight glass, flap, ball
Diaphragm / Limiter
Filtration
Manifold Block
B3. Fill Level / Limit Value / Level
- Accessories / Options
B4. Analysis

pH / ORP:
The measuring devices and the transducers operate with the standard pH and ORP measurement chains. The measuring devices are fitted with comprehensive monitoring functions of the measurement chains. For measuring tasks that are to be carried out over a great-er distance of 5 m to 100 m, the impedance converter pH40 is implemented.

Conductivity:
The conductive measurement of the conductivity of liquids for monitoring and controlling in the ongoing process is a varied measurement process in industry. In the pharmaceutical industry a high degree of hygiene and cleaning of the plants is necessary. This process is fulfilled by ultra-pure water.

O2, CO, CO2:
Oxygen ( O2) , carbon monoxide ( CO) and carbon dioxide ( CO2) measurements are mainly used for ambient air monitoring. CO2 and O2 are important indicators for ambient air quality and therefore important for modern climate control. The recommended CO2 limit for indoor air is 1000 ppm. Concentrations considerable above this limit causes fatigue and poor concentration. At values considerably lower than that limit there is a high energy saving potential at the climate control with optimized air change rates.
B5. Humidity
Humidity-Temperature-Transmitter incl. Sensor GHTU
2 x output 4..20 mA, 0..1 V or
0..10 V for humidity and temperature,
LC-Display 4-digit,
Supply voltage:
12..30 V DC at 4..20 mA, 0..1 V
18..30 V DC at 0..10 V
0..100 % r.h.,
-40..100 Â ° C

Humidity-Transmitter
Temperature measurement via Pt100,
Output:
0..10 V ( 3-wire)
4..20 mA ( 2-wire) ,
for humidity and temperature,
Supply voltage:
12..30 V DC at 4..20 mA
24 V DC at 0..10 V,
Rod shape, wall- and duct mounting
0..100 % r.h.,
-30..+ 70 Â ° C

B6. Pressure
GHTU

Humidity-Temperature-Transmitter incl. Sensor GHTU
2 x output 4..20 mA, 0..1 V or
0..10 V for humidity and temperature,
LC-Display 4-digit,
Supply voltage:
12..30 V DC at 4..20 mA, 0..1 V
18..30 V DC at 0..10 V
0..100 % r.h.,
-40..100 Â ° C
Data sheet

RF90

Humidity-Transmitter
Temperature measurement via Pt100,
Output:
0..10 V ( 3-wire)
4..20 mA ( 2-wire) ,
for humidity and temperature,
Supply voltage:
12..30 V DC at 4..20 mA
24 V DC at 0..10 V,
Rod shape, wall- and duct mounting
0..100 % r.h.,
-30..+ 70 Â ° C
Data sheet

B7. Weighing Instruments
Weighing instruments / Force
Precision measurement for sales and table scales
Industry applications like weighing bridges, big containers, tanks and silos
Wide range of applications like plate form, table scales, belt-, small container-, tank- and package weigher

Connection of all standard measuring cells
Large range of applications
Transmitter for DIN rail mounting
Panelmeter
Measuring ranges from 5 kg up to 100 t
Ex devices

Photo
Type
Description
Measuring input
Documents

DMS50
Transmitter with Profibus
 ± 9999( 0) Digit, LC-Display
Measuring programmable,
Line compensation via sense line,
max. 4 alarm outputs,
Analog output,
Supply voltage: 24 V DC, 115 V AC, 230 V AC,
DIN rail mounting TS35
Direct connection of DMS-cells,
Bridge sensitivity 0.1..5.0 mV/ V
Data sheet
DMS50EX
Transmitter with Profibus and Ex
 ± 9999( 0) Digit, LC-Display
Measuring programmable,
Line compensation via sense line,
max. 2 alarm outputs,
Analog output,
Supply voltage: 24 V DC, 115 V AC, 230 V AC,
DIN rail mounting TS35

Direct connection of DMS-cells,
Bridge sensitivity
0.5..5.0 mV/ V
Data sheet

DMS9648

DMS Bridge Panelmeter
 ± 9999( 0) Digit, 14, 2 mm red,
Measuring programmable,
Line compensation via sense line,
max. 4 alarm outputs,
Analog output,
Supply voltage: 24 V DC, 24 V AC, 115 V AC, 230 V AC
Panelmeter DIN 96x48 mm
Direct connection of DMS-cells,
Bridge sensitivity
0.9..6.6 mV/ V
Data sheet

SBB1616

DMS-Bridge Amplifier
Bridge supply 2..10 V
Line compensation up to 1 V
Supply voltage: 24 V DC, 24 V AC, 115 V AC, 230 V AC
Field case, aluminum
max. 6 DMS sensors connectable
Data sheet
Load cells

KR

High Power Load-Cell
Traction and force,
Line compensation via sense line,
Case material steel
50 kg..30 t
Data sheet

KS

Heavy load Load-Cell
Force power,
Line compensation via sense line,
Case material steel
50 kg..100 t
Data sheet

PC22

Precision Load-Cell
Standard and Ex-devices,
Line compensation via sense line,
Case material aluminum
5 kg..40 kg
Data sheet

SB8

Share-Beam Load-Cell
Standard and Ex-device,
Line compensation via sense line,
Case material SS-type 1.4548
10 kg..500 kg
Data sheet

ULB

DMS-Load-Cell
Standard and Ex-devices,
Line compensation via sense line,
Case material aluminum
100 kg..5000 kg
Data sheet

RC3

High Power Load-Cell
Standard and Ex-device,
Line compensation via sense line,
Case material SS-type 1.4548
7.5 kg..100 t
Data sheet

C: " Hygienic Design "
D: Laboratory Instrumentation
E: Industrial Electronics
F: Measurement Data Aquisition

C: Process Instrumentation Hygienic Designed
GHMadapt processconnection
Temperature
Magnetic Inductive Flow
Flow Calorimetric
Point Level Capacitive
Point Level Conductive
Level calorimetry

GHMsilverline - Features

Robust and water-proof housing
Water-proof connections and
water-proof probes, sensors or electrodes ( depending on meas. set)
Data logger function
Serial interface and analog output
Silicone protection cover
Large double display
Background illumination
Wide spectrum of measurands

GHMsilverline - Handheld measuring devices in a set

Each GHMsilverline set includes a complete measuring set containing the following components:
Water-proof handheld instrument
High-quality case
Flash drive wiht operating software and manual
USB adapter and cable with connection for analog output
Manufacturer ´ s calibration at delivery
Gratis manufacturer ´ s calibration after 1 year with automatic reminding from our calibration laboratory
Accessories like e.g. water-proof pH electrode and buffer solutions or water-proof temperature probe ( depending on set type)

E: Industrial Electronics

E1 Displays / Controller
E2 Transmitter
E3 Isolating Converter
E4 Safety and Monitoring
E 5 Power Electronic
E6 Calibrating and Testing

F: Measurement Data Aquisition

F1 Data logger / EASYBus
F2 Test Bench Measurement
F3 Renewable Energie

You may click the "Company Info" and "Contact Us" to browse and see other informations of CV ANDALAN PRIMA SEJAHTERA's website.


You have [3] new inquiries.
Go to Member Menu

Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indomonster.com. All Rights Reserved.